Factory Default Settings
Overview
Each SM5000 unit is pre-configured at the factory prior to shipment based on settings determined during pre-shipment consultation. This chapter describes every setting established before the device reaches the deployment site, what the factory defaults are, and which items require action by the commissioner.
All configuration settings are accessible and adjustable post-deployment via the device's built-in web interface. Refer to Chapter 2 for a full walkthrough.
1Network Configuration
Static IP by default. Each unit must be assigned a unique address during deployment. Refer to Section 2.3.
| IP Address | Determined during pre-shipment consultation |
| Subnet Mask | Determined during pre-shipment consultation |
| Default Gateway | Determined during pre-shipment consultation |
| DNS Server | Determined during pre-shipment consultation |
| DHCP | Factory default: Disabled |
| Action | Required |
| Assigned by | Commissioner |
| Scope | Each unit individually |
| Configured via | Web interface - §2.3 |
| All units ship with identical IP settings. Each device must be assigned a unique IP before connecting to a live network. | |
2Device Name
All units ship with the same default device name. Each must be individually assigned. Configured in MQTT settings - refer to Section 2.4.
| Factory Default | Uniform across all units |
| Naming Convention | Agreed during pre-shipment consultation |
| Typical Format | Encodes physical location (site, floor, row, position) |
| Configured via | Web interface - §2.4 |
| Action | Required |
| Assigned by | Commissioner |
| Scope | Each unit individually |
| All units ship with the same default name. Each must be assigned its unique name before registration with SyncFM. | |
3MQTT Configuration
Telemetry published every 30 seconds. All MQTT settings are pre-configured to match the deployment environment.
| MQTT Broker IP | Determined during pre-shipment consultation |
| MQTT Port | Factory default: 1883 |
| MQTT Username | Determined during pre-shipment consultation |
| MQTT Password | Determined during pre-shipment consultation |
| MQTT Enabled | Factory default: Enabled |
| Country | Two-letter country code |
| City | Three-letter city code |
| Datacentre | Datacentre identifier |
| Building | Building identifier |
| Floor | Floor number |
| Datahall | Datahall identifier |
| Device Name | Unique unit identifier |
{Country}/{City}/{Datacentre}/{Building}/{Floor}/{Datahall}/{DeviceName}4Device Configuration via Web Interface
All configurable settings on the SM5000 are accessible through the device's built-in web interface, reachable via a browser on the local network using the device's IP address. Access is protected by a username and password.
| Username | admin |
| Password | admin123 |
| Session Management | Token-based, single active session |
| Access Method | HTTP via device IP address |
| Network Settings | IP, Subnet, Gateway, DNS, DHCP |
| Device Name | Unit identifier |
| MQTT Settings | Broker, port, credentials, hierarchy |
| Modbus TCP | Enable / disable |
| Time Synchronisation | Source selection, NTP server |
| Sensor Calibration | Offset adjustment and reset |
| Web Interface Credentials | Username and password |
| Factory Reset | Restore all defaults |
5Modbus TCP
| Enabled / Disabled | Determined during pre-shipment consultation |
| Port | 502 (fixed) |
| Slave ID | 1 |
| Registers Available | 40001 - 40009 (9 holding registers) |
| Max Concurrent Clients | 5 |
40001 | Sensor 1 Temperature (×10°C) |
40002 | Sensor 1 Humidity (×10%RH) |
40003 | Sensor 2 Temperature (×10°C) |
40004 | Sensor 2 Humidity (×10%RH) |
40005 | Device Status (bitfield) |
40006-40007 | Uptime (seconds, 32-bit split) |
40008-40009 | IP Address (octets, split) |
6Time Synchronisation
| Default Source | Fleet Manager (SyncFM) |
| NTP Server (if NTP mode) | Determined during pre-shipment consultation |
| SyncFM Timeout | 5 minutes from boot |
| Fleet Manager | Time broadcast via MQTT. No internet required. |
| NTP | Requires network access to an NTP host. |
| Disabled | Internal clock only. Timestamps may drift. |
| Sensor 1 Temp Offset | Factory default: 0.0 °C |
| Sensor 1 Humidity Offset | Factory default: 0.0 %RH |
| Sensor 2 Temp Offset | Factory default: 0.0 °C |
| Sensor 2 Humidity Offset | Factory default: 0.0 %RH |
| Storage | Non-volatile memory |
| If pre-calibrated | Offsets documented in delivery record |
7Pre-Installed Firmware
| Firmware Version | Documented on delivery manifest |
| Update Method | OTA via SyncFM |
| OTA Security | HMAC-SHA256 verification |
| Max OTA Attempts | 3 (1 initial + 2 retries, 3-min intervals) |
| Stagger Method | MAC address-based, 30s per group |
| Network / IP | ⚠ Required - §2.3 |
| Device Name | ⚠ Required - §2.4 |
| MQTT Broker & Hierarchy | Pre-configured |
| SyncFM Endpoint | Pre-configured |
| Web Interface Password | ★ Recommended change |
| Modbus TCP | Pre-configured |
| Time Sync / Calibration | Pre-configured |
| Firmware Version | On delivery manifest |