Healthcare

Compliant, reliable building management for hospitals and aged care facilities where patient safety is paramount.

Standards Compliance

Real-Time Compliance Monitoring

AS 1668.2 ventilation, AS 2896 medical gas, NCC Section J energy efficiency and essential services — all verified continuously from a single pane of glass.

Healthcare Compliance Monitor|AS 1668.2 · NCC Section J · AS 2896
Live
|09/03/2026
100% Compliant
All monitored zones
10 Pass 0 Warn 0 Fail
Room Compliance | AS 1668.2 / NCC
10 zones monitored
StatusRoomTypeACHTemp °CRH %PressureStandard
PASSOperating Theatre 1Theatre22/2020.8(18-22)52%+25 Pa(+)AS 1668.2
PASSOperating Theatre 2Theatre21/2021.2(18-22)48%+24 Pa(+)AS 1668.2
PASSICU Ward AICU14/1222.4(21-24)45%+10 Pa(+)AS 1668.2
PASSIsolation Room 1Isolation13/1222.0(21-24)50%-30 Pa()AS 1668.2
PASSIsolation Room 2Isolation12/1223.1(21-24)55%-28 Pa()AS 1668.2
PASSRecovery BayRecovery16/1522.8(21-24)44%+8 Pa(+)AS 1668.2
PASSSterile StoreSterile12/1020.5(20-22)40%+15 Pa(+)AS/NZS 4187
PASSPharmacyPharmacy11/1021.0(20-22)42%+10 Pa(+)AS 1668.2
PASSPathology LabLab13/1221.4(20-22)46%-15 Pa()AS 1668.2
PASSGeneral Ward BWard7/623.2(21-24)48%0 Pa()AS 1668.2
NCC J6D3Compliant
HVAC Controls
Zone thermostats, dead band, economy cycles
AS 1668.2Verified
Ventilation
ACH rates, pressure cascades, filtration
AS 2896Normal
Medical Gas
O2, N2O, air, vacuum monitoring
AS 1670.1Active
Fire Integration
FIP, EWIS, smoke control interlock
AS/NZS 3003Monitored
Essential Power
UPS, generators, patient care areas
ISO 16484Connected
BACnet / BMS
Building automation, point integration
Medical Gas | AS 2896
Oxygen (O2)NORMAL
410kPa
350500 kPa
Nitrous OxideNORMAL
380kPa
300450 kPa
Medical AirNORMAL
420kPa
350500 kPa
VacuumNORMAL
-60kPa
-80-40 kPa
Carbon DioxideNORMAL
390kPa
300500 kPa
Essential Services
Generator 1STANDBY
Fuel: 92% | Last test: 5 Mar
Generator 2STANDBY
Fuel: 88% | Last test: 5 Mar
UPS Theatre BlockONLINE
Load: 34% | Battery: 100%
UPS ICU / EmergencyONLINE
Load: 41% | Battery: 100%
Fire Indicator PanelONLINE
All zones normal | 0 alarms
BMS ControllerONLINE
All points scanned | 0 faults
Critical Environments

Precision Control, Zero Compromise

Operating theatre pressure cascades, AS 1668.2 compliance monitoring and life-safety system oversight in real time.

Healthcare BMS | Pressure Cascade Monitor

Operating Theatre Suite | Pressure Cascade

Operating Theatre+25 Pa21.1°C · 56% RH · 20 ACH◈ CLOSEDScrub Room+15 Pa22°C · 50% RH · 15 ACH◈ CLOSEDAnaesthetic Room+10 Pa22°C · 51% RH · 15 ACH◈ CLOSEDCorridor0 Pa23.1°C · 44% RH · 6 ACHDirty Utility-10 Pa21.9°C · 45% RH · 10 ACH◈ CLOSEDClick doors to simulate open/close
Operating+25 Pa
Scrub+15 Pa
Anaesthetic+10 Pa
Corridor0 Pa
Dirty-10 Pa
AS 1668.2 COMPLIANT
Australian Standard for ventilation, healthcare facility requirements

Room Compliance Status

Operating Theatre
+25 Pa
Scrub Room
+15 Pa
Anaesthetic Room
+10 Pa
Corridor
0 Pa
Dirty Utility
-10 Pa
Air Changes / Hr
20 ACH
Min. required: 15 ACH
Temperature
21°C
Range: 20–22°C
Humidity
54% RH
Range: 30–60% RH
Particulate
ISO 5
HEPA 94% life rem.

System Redundancy

Primary AHUACTIVE
Backup AHUSTANDBY
Last switchover test: 3.2s, within 5s requirement
Last verification: | Auto-verified every 30s
All pressure cascades within specification. Last verified 30 seconds ago
Industry Challenges

The Problems You Face

Common challenges in the healthcare sector that we help you overcome.

Challenge 1

Maintaining precise temperature and pressure differentials in operating theatres, isolation rooms and clean zones as required by AS 1668.2

Challenge 2

Ensuring 100% system availability in life-safety-critical areas with no tolerance for BMS failures or communication outages

Challenge 3

Managing complex HVAC sequences that must adapt to infection control protocols, surgical schedules and seasonal variations

Ready to Transform Your Healthcare?

Let's discuss how our expertise in healthcare can deliver measurable results for your organisation.