Commercial & Mixed-Use

Transform your office tower or mixed-use development into a building that thinks for itself. Integrated systems that tell you what is happening, predict what needs attention and deliver 5-star NABERS performance while keeping tenants comfortable.

Live Intelligence

Your Building, Talking to You

Real-time visibility into every system, floor and zone. Your building tells you what is happening, what needs attention and what is coming next.

Nav|Px View
Commercial Tower A|09/03/2026

System Health

All Systems

Online Devices7/8
Offline1 Devices

System Alarms

All Systems

Total Alarms3
Critical Alarms2 Alarms

Central Plant Alarms

Plant Equipment

Total Equipment88
Equipment in Alarm1 Equipment

Comfort Condition

All Zones

Zones within Comfort20/24
Outside Comfort4 Zones

Building Cross-Section

Thermal overlay
Executive Suite22°
6
Boardroom21.8°
10
Roof Terrace24.2°
4
Open Plan West22.4°
24
Meeting Hub23.2°
16
Open Plan East22.1°
22
Tenant A22.3°
32
Tenant B22.5°
28
Open Plan West22.6°
20
Breakout23.4°
8
Open Plan East22.2°
26
Open Plan West22.4°
18
Meeting Rooms23.8°
12
Open Plan East22.1°
22
West Wing21.9°
15
Core / Comms24.6°
0
Boardroom21.5°
8
East Wing22.3°
20
Reception22°
5
Open Plan22.6°
28
Lab / Server20.1°
3
Lobby23.1°
10
Back of House22.8°
6
Plant Room26.2°
1
Comfort Warm Hot AHU

Quick Stats

Chilled Water System

Temperature within target range

10 minutes ago

DETAILS >

Heating Water System

Offline during warm outdoor condition

10 minutes ago

DETAILS >

Level 3 Floor Area

VAV damper position fault detected

10 minutes ago

DETAILS >

Filter Replacement Up to Date

All filters are clean

10 minutes ago

DETAILS >

Wall Sensors Require Attention

2 sensors have incorrect readings

10 minutes ago

DETAILS >
Space TemperatureGood
22.7°C
Zones Average
Performance
96.0%
Min Temp: 20.1°C
Max Temp: 26.2°C
Hot Zones: 2
Cold Zones: 1
Space CO2Good
612ppm
Zones Average
Performance
94.0%
Min CO2: 410 ppm
Max CO2: 855 ppm
High CO2 Zones: 1
Low CO2 Zones: 15
Space COGood
0.0ppm
Zones Average
Performance
100.0%
Min CO: 0.0 ppm
Max CO: 0.0 ppm
Central PlantGood
60.0%
Zones Average
Performance
60.0%
Supply CHWS: 6.0°C
Return CHWS: 12.0°C
Supply HWS: 50.0°C
Return HWS: 30.0°C
Power DemandLive
342.7kW
Energy Current Month560.5 kWh
Energy Previous Month670.1 kWh
Learn More >
All StatusSort by Name
All Devices | Last 24 Hours
StatusPointsDescriptionIP AddressT_SpaceT_Space_SPCO2Humidity
Z8_1L8 Executive Suite10.115.184.122.0°C22.0°C520 ppm44%
Z8_2L8 Boardroom10.115.184.221.8°C22.0°C580 ppm46%
Z8_3L8 Roof Terrace10.115.184.324.2°C24.0°C440 ppm50%
Z7_1L7 Open Plan West10.115.184.422.4°C22.0°C610 ppm45%
Z7_2L7 Meeting Hub10.115.184.523.2°C22.0°C720 ppm48%
Z7_3L7 Open Plan East10.115.184.622.1°C22.0°C590 ppm44%
Z6_1L6 Tenant A10.115.184.722.3°C22.0°C550 ppm43%
Z6_2L6 Tenant B10.115.184.822.5°C22.0°C640 ppm45%
Reporting

NABERS Rating & After Hours

Track your NABERS Energy performance and manage after-hours HVAC usage with full tenant cost attribution.

BMS Reporting Dashboard

Report Period: FY 2025-26
NABERS Energy Rating
5.5 / 6.0
Up from 5.0 stars (FY24)
Electricity
43,293
kWh/month
Gas
3,339
MJ/month
Water
371
m³/month
Monthly Utility Consumption (6 Months)
Electricity (kWh)
Gas (MJ)
Water (m³)
48.2k
1.9k
420
Jan
45.8k
2.1k
395
Feb
44.1k
2.5k
385
Mar
42.5k
3.2k
370
Apr
43.8k
3.6k
380
May
43.1k
3.4k
372
Jun
Base Building vs Tenant
62%
38%
Base BuildingTenant
Rating Position (Normalised Energy Score)
1 Star3 Stars5.5 ★6 Stars
After Hours HVAC Report
Requests (Month)
47
Energy Cost (Month)
$12,787
This Week (Daily Requests)
Mon
9
Tue
12
Wed
10
Thu
11
Fri
6
Top Requesting Tenants
1Level 4 - Law Firm14 req$3,820
2Level 3 - Accounting11 req$2,990
3Level 2 - Tech Co9 req$2,450
4Level 1 - Lobby/Admin8 req$2,180
5Level 4 - Meeting Rm5 req$1,400
Avg Duration
2.3 hrs
Auto-Cancel Rate
17%
After Hours Pattern (5pm - 11pm)
5pm
20%
6pm
85%
7pm
95%
8pm
70%
9pm
40%
10pm
20%
11pm
5%
Industry Challenges

The Problems You Face

Common challenges in the commercial & mixed-use sector that we help you overcome.

Challenge 1

Multiple building systems operating in isolation with no ability to share data, coordinate responses or provide a unified view of building health

Challenge 2

Reactive maintenance culture where equipment failures cause tenant disruption, emergency callouts and costly unplanned repairs

Challenge 3

Achieving and sustaining premium NABERS Energy ratings while balancing individual tenant comfort preferences across multi-tenancy configurations

Ready to Transform Your Commercial & Mixed-Use?

Let's discuss how our expertise in commercial & mixed-use can deliver measurable results for your organisation.